Properties:
RelatedCategories | AdditionalStandards,AnalyticalStandards,Analytical/Chromatography,ProficiencyTesting,WaterPollution/WasteWaterInorganics, |
packaging | ampuleof1×1.5 g |
mfr.no. | RTC,PEI-030 |
matrix | NaCl |
Description:
Generaldescription
ThisproficiencytestingsampleisproducedinaccordancewithISO/IEC17043:2010.Allinformationregardingtheuseofthismaterialcanbefoundinthereportingpacketsuppliedforeachsample.
OtherNotes
Proficiencytestingsamplesarepresentedassingleblind.Novaluesforthesamplesarereleaseduntilthetestingperiodconcludes.Valuesofanalytesvarylottolot.
ProficiencyTestingSchedule(2017-2018)
Wastewater
WP17-1January18-March3,2017
WP17-2March29-May12,2017
WP17-3AMay17-June30,2017
WP17-3BJuly12-August25,2017
WP17-4September27-November10,2017
WP17-5November22-January5,2018
WP18-1January17-March2,2018
WP18-2March28-May11,2018
WP18-3AMay16-June29,2018
WP18-3BJuly11-August24,2018
WP18-4September26-November9,2018
WP18-5November21-January4,2019
Quick-TurnStudy-(non-scheduledproficiencytestthatisavailableatanytime)
PreparationNote
ThisPTsampleisasolidconcentrate.
ThematrixforthissampleisNaCl.
SamplePreparation
Partiallyfilla1000mLvolumetricflaskwithreagent-gradewater.
OpencontainerPE1050-1.5Gandtransferentirecontentstovolumetricflask.
Transfertothevolumetricflaskusingaglassfunnel.
Rinsethevial,capandfunnelwithreagent-gradewaterandtransfertovolumetricflask.
Fillthevolumetricflasktovolume(1000mL)andmixbyinvertingtheflask10times.
Allowsampletorestfor10minutesandinvert10moretimes.
Immediatelyafterthesecondsetofinversions,rapidlymeasurea500-mLaliquotintoagraduatedcylinderbyrepetitivelymixingandpouringsoasnottoallowsolidstosettleintheflaskbeforethetransferiscomplete.
Thesampleisnowreadyforimmediateanalysis.
Filterthis500mLaliquotanddeterminetheanalytesaccordingtothechosenmethod(s).
Remembertocorrectbackto1000mL.
Safety:
Symbol
GHS08
RIDADR
NONHforallmodesoftransport